Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current50A
Rated insulation voltage Ui440V
Number of protected poles1
Release characteristicK
Rated impulse withstand voltage Uimp4kV
Frequency50 - 60Hz
Number of poles (total)1
Over voltage category3
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Voltage typeAC/DC
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated voltage230V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Built-in depth69mm
Width in number of modular spacings1
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 25mm²
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 35mm²
Pollution degree2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251001R0577 | S201-K50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

50A

Rated insulation voltage Ui

440V

Number of protected poles

1

Release characteristic

K

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 60Hz

Number of poles (total)

1

Over voltage category

3

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Voltage type

AC/DC

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated voltage

230V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Built-in depth

69mm

Width in number of modular spacings

1

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 35mm²

Pollution degree

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.