Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category3
Voltage typeAC/DC
Rated voltage230V
Current limiting class3
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Built-in depth69mm
Suitable for flush-mounted installationNo
Pollution degree2
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Explosion-proofNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 35mm²
Flush-mounted installationNo
Power loss5.2W
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Rated current63A
Release characteristicZ
Width in number of modular spacings1
Degree of protection (IP)IP20
Number of protected poles1
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251001R0608 | S201-Z 63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category

3

Voltage type

AC/DC

Rated voltage

230V

Current limiting class

3

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Built-in depth

69mm

Suitable for flush-mounted installation

Pollution degree

2

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Explosion-proof

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 35mm²

Flush-mounted installation

Power loss

5.2W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated current

63A

Release characteristic

Z

Width in number of modular spacings

1

Degree of protection (IP)

IP20

Number of protected poles

1

Concurrently switching neutral conductor

Additional equipment possible

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.