Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Release characteristicK
Voltage typeAC/DC
Frequency50 - 60Hz
Current limiting class3
Width in number of modular spacings2
Over voltage category3
Rated insulation voltage Ui440V
Pollution degree3
Rated voltage230V
Rated current1A
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0 - 35mm²
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired0 - 25mm²
Number of protected poles1
Ambient temperature during operating-25 - 55°C
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251103R0217 | S201-K 1 NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Release characteristic

K

Voltage type

AC/DC

Frequency

50 .. 60Hz

Current limiting class

3

Width in number of modular spacings

2

Over voltage category

3

Rated insulation voltage Ui

440V

Pollution degree

3

Rated voltage

230V

Rated current

1A

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 .. 35mm²

Additional equipment possible

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0 .. 25mm²

Number of protected poles

1

Ambient temperature during operating

-25 .. 55°C

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.