Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicZ
Voltage typeAC/DC
Width in number of modular spacings2
Pollution degree3
Rated voltage230V
Current limiting class3
Over voltage category3
Built-in depth69mm
Frequency50 - 60Hz
Rated current1.6A
Rated insulation voltage Ui440V
Number of protected poles1
Power loss5.6W
Explosion-proofNo
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired0 - 25mm²
Connectable conductor cross section solid-core0 - 35mm²
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Number of poles (total)2
Ambient temperature during operating-25 - 55°C
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251103R0258 | S201-Z 1.6 NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

Z

Voltage type

AC/DC

Width in number of modular spacings

2

Pollution degree

3

Rated voltage

230V

Current limiting class

3

Over voltage category

3

Built-in depth

69mm

Frequency

50 .. 60Hz

Rated current

1.6A

Rated insulation voltage Ui

440V

Number of protected poles

1

Power loss

5.6W

Explosion-proof

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0 .. 25mm²

Connectable conductor cross section solid-core

0 .. 35mm²

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Number of poles (total)

2

Ambient temperature during operating

-25 .. 55°C

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.