  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage230V
Rated current3A
Voltage typeAC/DC
Release characteristicZ
Frequency50 - 60Hz
Built-in depth69mm
Current limiting class3
Explosion-proofNo
Degree of protection (IP)IP20
Width in number of modular spacings2
Over voltage category3
Pollution degree3
Power loss4.8W
Rated insulation voltage Ui440V
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 35mm²
Ambient temperature during operating-25 - 55°C
Flush-mounted installationNo
Number of protected poles1
Additional equipment possibleYes
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251103R0318 | S201-Z 3 NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

230V

Rated current

3A

Voltage type

AC/DC

Release characteristic

Z

Frequency

50 .. 60Hz

Built-in depth

69mm

Current limiting class

3

Explosion-proof

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Over voltage category

3

Pollution degree

3

Power loss

4.8W

Rated insulation voltage Ui

440V

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Flush-mounted installation

Number of protected poles

1

Additional equipment possible

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Number of poles (total)

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.