Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicK
Voltage typeAC/DC
Rated current16A
Rated voltage230V
Built-in depth69mm
Rated insulation voltage Ui440V
Current limiting class3
Frequency50 - 60Hz
Width in number of modular spacings2
Pollution degree3
Over voltage category3
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Number of poles (total)2
Number of protected poles1
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleYes
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Concurrently switching neutral conductorYes
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251103R0467 | S201-K 16 NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Voltage type

AC/DC

Rated current

16A

Rated voltage

230V

Built-in depth

69mm

Rated insulation voltage Ui

440V

Current limiting class

3

Frequency

50 .. 60Hz

Width in number of modular spacings

2

Pollution degree

3

Over voltage category

3

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Number of poles (total)

2

Number of protected poles

1

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.