Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Rated insulation voltage Ui440V
Suitable for flush-mounted installationNo
Current limiting class3
Connectable conductor cross section solid-core0 - 35mm²
Over voltage category3
Pollution degree3
Frequency50 - 60Hz
Power loss5.6W
Explosion-proofNo
Built-in depth69mm
Flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0 - 25mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
Rated current16A
Rated voltage230V
Release characteristicZ
Width in number of modular spacings2
Degree of protection (IP)IP20
Number of protected poles1
Concurrently switching neutral conductorYes
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251103R0468 | S201-Z 16 NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Rated insulation voltage Ui

440V

Suitable for flush-mounted installation

Current limiting class

3

Connectable conductor cross section solid-core

0 .. 35mm²

Over voltage category

3

Pollution degree

3

Frequency

50 .. 60Hz

Power loss

5.6W

Explosion-proof

Built-in depth

69mm

Flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 25mm²

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

Rated current

16A

Rated voltage

230V

Release characteristic

Z

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Number of protected poles

1

Concurrently switching neutral conductor

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.