Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Frequency50 - 60Hz
Current limiting class3
Rated insulation voltage Ui440V
Connectable conductor cross section solid-core0 - 35mm²
Suitable for flush-mounted installationNo
Degree of protection (IP)IP20
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Width in number of modular spacings2
Ambient temperature during operating-25 - 55°C
Over voltage category3
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Pollution degree3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Number of poles (total)2
Release characteristicC
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of protected poles1
Concurrently switching neutral conductorYes
Voltage typeAC
Rated voltage230V
Rated current50A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251103R0504 | S201-C 50 NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Frequency

50 .. 60Hz

Current limiting class

3

Rated insulation voltage Ui

440V

Connectable conductor cross section solid-core

0 .. 35mm²

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 55°C

Over voltage category

3

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Number of poles (total)

2

Release characteristic

C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

1

Concurrently switching neutral conductor

Voltage type

AC

Rated voltage

230V

Rated current

50A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.