Aleta.hr
Main Product Image

2CDS252001R0061 | S202-D6

Code: 1549219

ManufacturerRAZNO
Catalog number2CDS252001R0061
Type
EAN code4016779530545

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

D

Number of poles (total)

2

Rated voltage

400V

Rated current

6A

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Current limiting class

3

Suitable for flush-mounted installation

No

Over voltage category

3

Frequency

50 - 60Hz

Concurrently switching neutral conductor

No

Built-in depth

68mm

Additional equipment possible

Yes

Pollution degree

3

Ambient temperature during operating

-25 - 55°C

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Voltage type

AC/DC

Connectable conductor cross section multi-wired

0 - 25mm²

Connectable conductor cross section solid-core

0 - 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS252001R0061 | S202-D6

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

D

Number of poles (total)

2

Rated voltage

400V

Rated current

6A

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Current limiting class

3

Suitable for flush-mounted installation

Over voltage category

3

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Built-in depth

68mm

Additional equipment possible

Pollution degree

3

Ambient temperature during operating

-25 .. 55°C

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Voltage type

AC/DC

Connectable conductor cross section multi-wired

0 .. 25mm²

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA