  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth68mm
Voltage typeAC/DC
Explosion-proofNo
Pollution degree3
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Current limiting class3
Connectable conductor cross section solid-core0 - 35mm²
Suitable for flush-mounted installationNo
Over voltage category3
Concurrently switching neutral conductorNo
Power loss4.8W
Flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Release characteristicZ
Number of poles (total)2
Number of protected poles2
Rated current0.5A
Rated voltage400V
Degree of protection (IP)IP20
Width in number of modular spacings2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS252001R0158 | S202-Z 0.5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

68mm

Voltage type

AC/DC

Explosion-proof

Pollution degree

3

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Current limiting class

3

Connectable conductor cross section solid-core

0 .. 35mm²

Suitable for flush-mounted installation

Over voltage category

3

Concurrently switching neutral conductor

Power loss

4.8W

Flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Release characteristic

Z

Number of poles (total)

2

Number of protected poles

2

Rated current

0.5A

Rated voltage

400V

Degree of protection (IP)

IP20

Width in number of modular spacings

2