Technical specifications

Voltage typeAC/DC
Rated current4A
Rated voltage400V
Release characteristicZ
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Over voltage category3
Power loss4.8W
Explosion-proofNo
Pollution degree3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated insulation voltage Ui440V
Number of protected poles2
Current limiting class3
Width in number of modular spacings2
Ambient temperature during operating-25 - 55°C
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0 - 35mm²
Connectable conductor cross section multi-wired0 - 25mm²
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Number of poles (total)2
Built-in depth69mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS252001R0338 | S202-Z 4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Rated current

4A

Rated voltage

400V

Release characteristic

Z

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Flush-mounted installation

Over voltage category

3

Power loss

4.8W

Explosion-proof

Pollution degree

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated insulation voltage Ui

440V

Number of protected poles

2

Current limiting class

3

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 55°C

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 .. 35mm²

Connectable conductor cross section multi-wired

0 .. 25mm²

Suitable for flush-mounted installation

Additional equipment possible

Number of poles (total)

2

Built-in depth

69mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA