Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicZ
Pollution degree3
Width in number of modular spacings2
Rated voltage400V
Over voltage category3
Current limiting class3
Frequency50 - 60Hz
Built-in depth69mm
Rated current6A
Rated insulation voltage Ui440V
Voltage typeAC/DC
Explosion-proofNo
Degree of protection (IP)IP20
Power loss6.4W
Number of protected poles2
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 35mm²
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Additional equipment possibleYes
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Connectable conductor cross section multi-wired0 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS252001R0378 | S202-Z 6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

Z

Pollution degree

3

Width in number of modular spacings

2

Rated voltage

400V

Over voltage category

3

Current limiting class

3

Frequency

50 .. 60Hz

Built-in depth

69mm

Rated current

6A

Rated insulation voltage Ui

440V

Voltage type

AC/DC

Explosion-proof

Degree of protection (IP)

IP20

Power loss

6.4W

Number of protected poles

2

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 35mm²

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Additional equipment possible

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Connectable conductor cross section multi-wired

0 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.