Technical specifications

Voltage typeAC/DC
Rated voltage400V
Frequency50 - 60Hz
Release characteristicD
Degree of protection (IP)IP20
Built-in depth69mm
Width in number of modular spacings2
Pollution degree3
Rated insulation voltage Ui440V
Current limiting class3
Rated current40A
Over voltage category3
Number of protected poles2
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Connectable conductor cross section multi-wired0 - 25mm²
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Ambient temperature during operating-25 - 55°C
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS252001R0401 | S202-D40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Rated voltage

400V

Frequency

50 .. 60Hz

Release characteristic

D

Degree of protection (IP)

IP20

Built-in depth

69mm

Width in number of modular spacings

2

Pollution degree

3

Rated insulation voltage Ui

440V

Current limiting class

3

Rated current

40A

Over voltage category

3

Number of protected poles

2

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Connectable conductor cross section multi-wired

0 .. 25mm²

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Ambient temperature during operating

-25 .. 55°C

Additional equipment possible

Suitable for flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

From same serie