Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Built-in depth69mm
Rated voltage400V
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired0 - 25mm²
Suitable for flush-mounted installationNo
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Width in number of modular spacings2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Connectable conductor cross section solid-core0 - 35mm²
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Current limiting class3
Pollution degree3
Over voltage category3
Rated current10A
Release characteristicK
Number of protected poles2
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS252001R0427 | S202-K10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Built-in depth

69mm

Rated voltage

400V

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

0 .. 25mm²

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Additional equipment possible

Concurrently switching neutral conductor

Width in number of modular spacings

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Connectable conductor cross section solid-core

0 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Current limiting class

3

Pollution degree

3

Over voltage category

3

Rated current

10A

Release characteristic

K

Number of protected poles

2

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.