Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Rated current16A
Built-in depth69mm
Rated voltage400V
Pollution degree3
Release characteristicZ
Number of protected poles2
Degree of protection (IP)IP20
Width in number of modular spacings2
Concurrently switching neutral conductorNo
Power loss5.6W
Ambient temperature during operating-25 - 55°C
Over voltage category3
Explosion-proofNo
Rated insulation voltage Ui440V
Suitable for flush-mounted installationNo
Frequency50 - 60Hz
Current limiting class3
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Rated impulse withstand voltage Uimp4kV
Number of poles (total)2
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Connectable conductor cross section solid-core0 - 35mm²
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS252001R0468 | S202-Z 16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Rated current

16A

Built-in depth

69mm

Rated voltage

400V

Pollution degree

3

Release characteristic

Z

Number of protected poles

2

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Concurrently switching neutral conductor

Power loss

5.6W

Ambient temperature during operating

-25 .. 55°C

Over voltage category

3

Explosion-proof

Rated insulation voltage Ui

440V

Suitable for flush-mounted installation

Frequency

50 .. 60Hz

Current limiting class

3

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Connectable conductor cross section solid-core

0 .. 35mm²

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.