Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)2
Rated insulation voltage Ui440V
Rated voltage400V
Rated current0.5A
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Voltage typeAC/DC
Release characteristicD
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Suitable for flush-mounted installationNo
Current limiting class3
Over voltage category3
Pollution degree3
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 25mm²
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 35mm²
Built-in depth69mm
Width in number of modular spacings2
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS252001R0981 | S202-D0,5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Rated insulation voltage Ui

440V

Rated voltage

400V

Rated current

0.5A

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Voltage type

AC/DC

Release characteristic

D

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Suitable for flush-mounted installation

Current limiting class

3

Over voltage category

3

Pollution degree

3

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 35mm²

Built-in depth

69mm

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.