Aleta.hr
Main Product Image

2CDS253001R0031 | S203-D3

Code: 1549307

ManufacturerABB
Catalog number2CDS253001R0031
EAN code4016779530859

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)3
Rated current3A
Number of protected poles3
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Release characteristicD
Rated insulation voltage Ui440V
Current limiting class3
Pollution degree3
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Over voltage category3
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Connectable conductor cross section solid-core0 - 35mm²
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0 - 25mm²
Rated voltage400V
Ambient temperature during operating-25 - 55°C
Width in number of modular spacings3
Built-in depth69mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS253001R0031 | S203-D3

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

3

Rated current

3A

Number of protected poles

3

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Release characteristic

D

Rated insulation voltage Ui

440V

Current limiting class

3

Pollution degree

3

Suitable for flush-mounted installation

Additional equipment possible

Over voltage category

3

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Connectable conductor cross section solid-core

0 .. 35mm²

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated voltage

400V

Ambient temperature during operating

-25 .. 55°C

Width in number of modular spacings

3

Built-in depth

69mm