Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicB
Pollution degree3
Rated insulation voltage Ui440V
Degree of protection (IP)IP20
Current limiting class3
Width in number of modular spacings3
Over voltage category3
Connectable conductor cross section multi-wired0 - 25mm²
Additional equipment possibleYes
Voltage typeAC
Rated current13A
Connectable conductor cross section solid-core0 - 35mm²
Built-in depth69mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Number of poles (total)3
Frequency50 - 60Hz
Ambient temperature during operating-25 - 55°C
Number of protected poles3
Rated voltage400V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS253001R0135 | S203-B13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Pollution degree

3

Rated insulation voltage Ui

440V

Degree of protection (IP)

IP20

Current limiting class

3

Width in number of modular spacings

3

Over voltage category

3

Connectable conductor cross section multi-wired

0 .. 25mm²

Additional equipment possible

Voltage type

AC

Rated current

13A

Connectable conductor cross section solid-core

0 .. 35mm²

Built-in depth

69mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Number of poles (total)

3

Frequency

50 .. 60Hz

Ambient temperature during operating

-25 .. 55°C

Number of protected poles

3

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.