  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Built-in depth69mm
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Connectable conductor cross section multi-wired0 - 25mm²
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 35mm²
Over voltage category3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Suitable for flush-mounted installationNo
Degree of protection (IP)IP20
Pollution degree3
Rated impulse withstand voltage Uimp4kV
Rated current1.6A
Rated voltage400V
Release characteristicK
Width in number of modular spacings3
Number of protected poles3
Concurrently switching neutral conductorNo
Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS253001R0257 | S203-K1,6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Built-in depth

69mm

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Connectable conductor cross section multi-wired

0 .. 25mm²

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 35mm²

Over voltage category

3

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Pollution degree

3

Rated impulse withstand voltage Uimp

4kV

Rated current

1.6A

Rated voltage

400V

Release characteristic

K

Width in number of modular spacings

3

Number of protected poles

3

Concurrently switching neutral conductor

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA