Aleta.hr
Main Product Image

2CDS253001R0257 | S203-K1,6

Code: 1549335

ManufacturerABB
Catalog number2CDS253001R0257
EAN code4016779507486

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicK
Rated insulation voltage Ui440V
Number of poles (total)3
Number of protected poles3
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Current limiting class3
Voltage typeAC
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Rated current1.6A
Over voltage category3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Pollution degree3
Additional equipment possibleYes
Built-in depth69mm
Width in number of modular spacings3
Suitable for flush-mounted installationNo
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0 - 25mm²
Connectable conductor cross section solid-core0 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS253001R0257 | S203-K1,6

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Rated insulation voltage Ui

440V

Number of poles (total)

3

Number of protected poles

3

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Current limiting class

3

Voltage type

AC

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Rated current

1.6A

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Pollution degree

3

Additional equipment possible

Built-in depth

69mm

Width in number of modular spacings

3

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 25mm²

Connectable conductor cross section solid-core

0 .. 35mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.