Technical specifications

Built-in depth69mm
Frequency50 - 60Hz
Current limiting class3
Rated insulation voltage Ui440V
Pollution degree3
Over voltage category3
Explosion-proofNo
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Flush-mounted installationNo
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0 - 25mm²
Additional equipment possibleYes
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
Power loss7.2W
Voltage typeAC
Rated current4A
Rated voltage400V
Release characteristicZ
Width in number of modular spacings3
Number of protected poles3
Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS253001R0338 | S203-Z 4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Frequency

50 .. 60Hz

Current limiting class

3

Rated insulation voltage Ui

440V

Pollution degree

3

Over voltage category

3

Explosion-proof

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Flush-mounted installation

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 25mm²

Additional equipment possible

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

Power loss

7.2W

Voltage type

AC

Rated current

4A

Rated voltage

400V

Release characteristic

Z

Width in number of modular spacings

3

Number of protected poles

3

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.