Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicC
Frequency50 - 60Hz
Pollution degree3
Number of protected poles3
Built-in depth69mm
Rated insulation voltage Ui440V
Current limiting class3
Degree of protection (IP)IP20
Power loss14.4W
Rated voltage400V
Width in number of modular spacings3
Voltage typeAC
Rated current40A
Concurrently switching neutral conductorNo
Over voltage category3
Explosion-proofNo
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Number of poles (total)3
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA

Recommended products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS253001R0404 | S203-C40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Frequency

50 .. 60Hz

Pollution degree

3

Number of protected poles

3

Built-in depth

69mm

Rated insulation voltage Ui

440V

Current limiting class

3

Degree of protection (IP)

IP20

Power loss

14.4W

Rated voltage

400V

Width in number of modular spacings

3

Voltage type

AC

Rated current

40A

Concurrently switching neutral conductor

Over voltage category

3

Explosion-proof

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Number of poles (total)

3

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA