Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage400V
Rated current20A
Release characteristicK
Built-in depth69mm
Current limiting class3
Frequency50 - 60Hz
Number of protected poles3
Rated insulation voltage Ui440V
Voltage typeAC
Degree of protection (IP)IP20
Pollution degree3
Width in number of modular spacings3
Over voltage category3
Connectable conductor cross section multi-wired0 - 25mm²
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Ambient temperature during operating-25 - 55°C
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS253001R0487 | S203-K20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Rated current

20A

Release characteristic

K

Built-in depth

69mm

Current limiting class

3

Frequency

50 .. 60Hz

Number of protected poles

3

Rated insulation voltage Ui

440V

Voltage type

AC

Degree of protection (IP)

IP20

Pollution degree

3

Width in number of modular spacings

3

Over voltage category

3

Connectable conductor cross section multi-wired

0 .. 25mm²

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Ambient temperature during operating

-25 .. 55°C

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.