  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Width in number of modular spacings4
Built-in depth69mm
Pollution degree3
Voltage typeAC
Over voltage category3
Release characteristicZ
Frequency50 - 60Hz
Explosion-proofNo
Rated current1A
Current limiting class3
Rated insulation voltage Ui440V
Connectable conductor cross section multi-wired0 - 25mm²
Concurrently switching neutral conductorYes
Rated voltage400V
Connectable conductor cross section solid-core0 - 35mm²
Ambient temperature during operating-25 - 55°C
Suitable for flush-mounted installationNo
Flush-mounted installationNo
Number of protected poles3
Degree of protection (IP)IP20
Power loss9.2W
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS253103R0218 | S203-Z 1 NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Width in number of modular spacings

4

Built-in depth

69mm

Pollution degree

3

Voltage type

AC

Over voltage category

3

Release characteristic

Z

Frequency

50 .. 60Hz

Explosion-proof

Rated current

1A

Current limiting class

3

Rated insulation voltage Ui

440V

Connectable conductor cross section multi-wired

0 .. 25mm²

Concurrently switching neutral conductor

Rated voltage

400V

Connectable conductor cross section solid-core

0 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Suitable for flush-mounted installation

Flush-mounted installation

Number of protected poles

3

Degree of protection (IP)

IP20

Power loss

9.2W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA