Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Voltage typeAC
Suitable for flush-mounted installationNo
Over voltage category3
Frequency50 - 60Hz
Explosion-proofNo
Width in number of modular spacings4
Rated insulation voltage Ui440V
Current limiting class3
Power loss11.2W
Degree of protection (IP)IP20
Rated voltage400V
Pollution degree3
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Connectable conductor cross section solid-core0 - 35mm²
Additional equipment possibleYes
Flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
Rated current1.6A
Release characteristicZ
Number of protected poles3
Concurrently switching neutral conductorYes
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS253103R0258 | S203-Z 1.6 NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Voltage type

AC

Suitable for flush-mounted installation

Over voltage category

3

Frequency

50 .. 60Hz

Explosion-proof

Width in number of modular spacings

4

Rated insulation voltage Ui

440V

Current limiting class

3

Power loss

11.2W

Degree of protection (IP)

IP20

Rated voltage

400V

Pollution degree

3

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Connectable conductor cross section solid-core

0 .. 35mm²

Additional equipment possible

Flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

Rated current

1.6A

Release characteristic

Z

Number of protected poles

3

Concurrently switching neutral conductor

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.