Technical specifications

Degree of protection (IP)IP20
Voltage typeAC
Suitable for flush-mounted installationNo
Built-in depth69mm
Rated voltage400V
Rated current8A
Width in number of modular spacings4
Release characteristicZ
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0 - 25mm²
Number of protected poles3
Connectable conductor cross section solid-core0 - 35mm²
Over voltage category3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated insulation voltage Ui440V
Number of poles (total)4
Rated impulse withstand voltage Uimp4kV
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Additional equipment possibleYes
Pollution degree3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Power loss8W
Flush-mounted installationNo
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS253103R0408 | S203-Z 8 NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Built-in depth

69mm

Rated voltage

400V

Rated current

8A

Width in number of modular spacings

4

Release characteristic

Z

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 25mm²

Number of protected poles

3

Connectable conductor cross section solid-core

0 .. 35mm²

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated insulation voltage Ui

440V

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Additional equipment possible

Pollution degree

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Power loss

8W

Flush-mounted installation

Explosion-proof