Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Rated insulation voltage Ui440V
Ambient temperature during operating-25 - 55°C
Built-in depth69mm
Degree of protection (IP)IP20
Over voltage category3
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 25mm²
Pollution degree3
Explosion-proofNo
Suitable for flush-mounted installationNo
Current limiting class3
Power loss14.4W
Flush-mounted installationNo
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
Number of poles (total)4
Release characteristicZ
Number of protected poles3
Rated current32A
Rated voltage400V
Voltage typeAC
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Width in number of modular spacings4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS253103R0538 | S203-Z 32 NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Ambient temperature during operating

-25 .. 55°C

Built-in depth

69mm

Degree of protection (IP)

IP20

Over voltage category

3

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Pollution degree

3

Explosion-proof

Suitable for flush-mounted installation

Current limiting class

3

Power loss

14.4W

Flush-mounted installation

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

4

Release characteristic

Z

Number of protected poles

3

Rated current

32A

Rated voltage

400V

Voltage type

AC

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Width in number of modular spacings

4

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.