Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)4
Release characteristicD
Number of protected poles4
Rated current2A
Rated insulation voltage Ui440V
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Frequency50 - 60Hz
Voltage typeAC/DC
Rated impulse withstand voltage Uimp4kV
Current limiting class3
Concurrently switching neutral conductorNo
Over voltage category3
Suitable for flush-mounted installationNo
Built-in depth69mm
Width in number of modular spacings4
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Additional equipment possibleYes
Ambient temperature during operating-25 - 55°C
Pollution degree3
Connectable conductor cross section multi-wired0 - 25mm²
Connectable conductor cross section solid-core0 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS254001R0021 | S204-D2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Release characteristic

D

Number of protected poles

4

Rated current

2A

Rated insulation voltage Ui

440V

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Frequency

50 .. 60Hz

Voltage type

AC/DC

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Concurrently switching neutral conductor

Over voltage category

3

Suitable for flush-mounted installation

Built-in depth

69mm

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Additional equipment possible

Ambient temperature during operating

-25 .. 55°C

Pollution degree

3

Connectable conductor cross section multi-wired

0 .. 25mm²

Connectable conductor cross section solid-core

0 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.