Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Frequency50 - 60Hz
Connectable conductor cross section solid-core0 - 35mm²
Suitable for flush-mounted installationNo
Rated insulation voltage Ui440V
Pollution degree3
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired0 - 25mm²
Additional equipment possibleYes
Ambient temperature during operating-25 - 55°C
Current limiting class3
Concurrently switching neutral conductorNo
Release characteristicD
Rated current10A
Number of protected poles4
Number of poles (total)4
Rated voltage400V
Degree of protection (IP)IP20
Width in number of modular spacings4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS254001R0101 | S204-D10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Frequency

50 .. 60Hz

Connectable conductor cross section solid-core

0 .. 35mm²

Suitable for flush-mounted installation

Rated insulation voltage Ui

440V

Pollution degree

3

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

0 .. 25mm²

Additional equipment possible

Ambient temperature during operating

-25 .. 55°C

Current limiting class

3

Concurrently switching neutral conductor

Release characteristic

D

Rated current

10A

Number of protected poles

4

Number of poles (total)

4

Rated voltage

400V

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.