Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current50A
Built-in depth69mm
Voltage typeAC/DC
Pollution degree3
Rated voltage400V
Width in number of modular spacings4
Release characteristicC
Frequency50 - 60Hz
Current limiting class3
Rated insulation voltage Ui440V
Suitable for flush-mounted installationNo
Over voltage category3
Explosion-proofNo
Connectable conductor cross section solid-core0 - 35mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Number of poles (total)4
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated impulse withstand voltage Uimp4kV
Power loss13W
Connectable conductor cross section multi-wired0 - 25mm²
Ambient temperature during operating-25 - 55°C
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Number of protected poles4

Recommended products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS254001R0504 | S204-C50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

50A

Built-in depth

69mm

Voltage type

AC/DC

Pollution degree

3

Rated voltage

400V

Width in number of modular spacings

4

Release characteristic

C

Frequency

50 .. 60Hz

Current limiting class

3

Rated insulation voltage Ui

440V

Suitable for flush-mounted installation

Over voltage category

3

Explosion-proof

Connectable conductor cross section solid-core

0 .. 35mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Number of poles (total)

4

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated impulse withstand voltage Uimp

4kV

Power loss

13W

Connectable conductor cross section multi-wired

0 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Number of protected poles

4