Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Voltage typeAC/DC
Pollution degree3
Rated voltage400V
Frequency50 - 60Hz
Current limiting class3
Rated insulation voltage Ui440V
Suitable for flush-mounted installationNo
Over voltage category3
Explosion-proofNo
Connectable conductor cross section solid-core0 - 35mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Power loss13W
Connectable conductor cross section multi-wired0 - 25mm²
Ambient temperature during operating-25 - 55°C
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Width in number of modular spacings4
Number of protected poles4
Rated current50A
Release characteristicC
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA

Recommended products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS254001R0504 | S204-C50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Voltage type

AC/DC

Pollution degree

3

Rated voltage

400V

Frequency

50 .. 60Hz

Current limiting class

3

Rated insulation voltage Ui

440V

Suitable for flush-mounted installation

Over voltage category

3

Explosion-proof

Connectable conductor cross section solid-core

0 .. 35mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Power loss

13W

Connectable conductor cross section multi-wired

0 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Width in number of modular spacings

4

Number of protected poles

4

Rated current

50A

Release characteristic

C

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

From same serie

Recommended products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.