Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicD
Rated voltage400V
Voltage typeAC/DC
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Rated current63A
Pollution degree3
Concurrently switching neutral conductorNo
Width in number of modular spacings4
Degree of protection (IP)IP20
Number of protected poles4
Current limiting class3
Over voltage category3
Built-in depth69mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Suitable for flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Number of poles (total)4
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Connectable conductor cross section multi-wired0 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS254001R0631 | S204-D63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

D

Rated voltage

400V

Voltage type

AC/DC

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Rated current

63A

Pollution degree

3

Concurrently switching neutral conductor

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Number of protected poles

4

Current limiting class

3

Over voltage category

3

Built-in depth

69mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Suitable for flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

4

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Connectable conductor cross section multi-wired

0 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.