Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Built-in depth69mm
Rated current63A
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Release characteristicB
Width in number of modular spacings4
Concurrently switching neutral conductorNo
Rated voltage400V
Current limiting class3
Degree of protection (IP)IP20
Pollution degree3
Number of protected poles4
Over voltage category3
Connectable conductor cross section solid-core0 - 35mm²
Number of poles (total)4
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 25mm²
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS254001R0635 | S204-B63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Built-in depth

69mm

Rated current

63A

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Release characteristic

B

Width in number of modular spacings

4

Concurrently switching neutral conductor

Rated voltage

400V

Current limiting class

3

Degree of protection (IP)

IP20

Pollution degree

3

Number of protected poles

4

Over voltage category

3

Connectable conductor cross section solid-core

0 .. 35mm²

Number of poles (total)

4

Suitable for flush-mounted installation

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.