Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Frequency50 - 60Hz
Release characteristicD
Rated current3A
Built-in depth69mm
Rated voltage230V
Current limiting class3
Over voltage category3
Width in number of modular spacings1
Number of protected poles1
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorNo
Pollution degree3
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Ambient temperature during operating-25 - 55°C
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Additional equipment possibleYes
Rated insulation voltage Ui440V
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271001R0031 | S201M-D3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Frequency

50 .. 60Hz

Release characteristic

D

Rated current

3A

Built-in depth

69mm

Rated voltage

230V

Current limiting class

3

Over voltage category

3

Width in number of modular spacings

1

Number of protected poles

1

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Pollution degree

3

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Ambient temperature during operating

-25 .. 55°C

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Additional equipment possible

Rated insulation voltage Ui

440V

Degree of protection (IP)

IP20

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.