Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated insulation voltage Ui440V
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated voltage230V
Release characteristicK
Number of protected poles1
Rated current3A
Rated impulse withstand voltage Uimp4kV
Degree of protection (IP)IP20
Voltage typeAC/DC
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Over voltage category3
Pollution degree3
Ambient temperature during operating-25 - 55°C
Width in number of modular spacings1
Built-in depth69mm
Current limiting class3
Connectable conductor cross section solid-core0 - 35mm²
Connectable conductor cross section multi-wired0 - 25mm²
Frequency50 - 60Hz
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271001R0317 | S201M-K3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated insulation voltage Ui

440V

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated voltage

230V

Release characteristic

K

Number of protected poles

1

Rated current

3A

Rated impulse withstand voltage Uimp

4kV

Degree of protection (IP)

IP20

Voltage type

AC/DC

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Additional equipment possible

Over voltage category

3

Pollution degree

3

Ambient temperature during operating

-25 .. 55°C

Width in number of modular spacings

1

Built-in depth

69mm

Current limiting class

3

Connectable conductor cross section solid-core

0 .. 35mm²

Connectable conductor cross section multi-wired

0 .. 25mm²

Frequency

50 .. 60Hz

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.