Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Built-in depth69mm
Release characteristicC
Frequency50 - 60Hz
Current limiting class3
Over voltage category3
Rated current32A
Rated voltage230V
Pollution degree3
Rated insulation voltage Ui440V
Width in number of modular spacings1
Number of protected poles1
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0 - 25mm²
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 35mm²
Concurrently switching neutral conductorNo
Number of poles (total)1
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271001R0324 | S201M-C32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Built-in depth

69mm

Release characteristic

C

Frequency

50 .. 60Hz

Current limiting class

3

Over voltage category

3

Rated current

32A

Rated voltage

230V

Pollution degree

3

Rated insulation voltage Ui

440V

Width in number of modular spacings

1

Number of protected poles

1

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 25mm²

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 35mm²

Concurrently switching neutral conductor

Number of poles (total)

1

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

From same serie