Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Rated current4A
Frequency50 - 60Hz
Built-in depth69mm
Rated voltage230V
Release characteristicK
Over voltage category3
Current limiting class3
Rated insulation voltage Ui440V
Number of protected poles1
Pollution degree3
Width in number of modular spacings1
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0 - 25mm²
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 35mm²
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271001R0337 | S201M-K4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Rated current

4A

Frequency

50 .. 60Hz

Built-in depth

69mm

Rated voltage

230V

Release characteristic

K

Over voltage category

3

Current limiting class

3

Rated insulation voltage Ui

440V

Number of protected poles

1

Pollution degree

3

Width in number of modular spacings

1

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 25mm²

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.