Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui440V
Frequency50 - 60Hz
Rated current40A
Rated voltage230V
Current limiting class3
Over voltage category3
Release characteristicK
Pollution degree3
Built-in depth69mm
Voltage typeAC/DC
Suitable for flush-mounted installationNo
Degree of protection (IP)IP20
Width in number of modular spacings1
Concurrently switching neutral conductorNo
Number of protected poles1
Number of poles (total)1
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core0 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271001R0557 | S201M-K40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Rated current

40A

Rated voltage

230V

Current limiting class

3

Over voltage category

3

Release characteristic

K

Pollution degree

3

Built-in depth

69mm

Voltage type

AC/DC

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Width in number of modular spacings

1

Concurrently switching neutral conductor

Number of protected poles

1

Number of poles (total)

1

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

0 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.