Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Release characteristicK
Rated impulse withstand voltage Uimp4kV
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Voltage typeAC/DC
Number of protected poles1
Current limiting class3
Additional equipment possibleYes
Over voltage category3
Number of poles (total)1
Pollution degree3
Width in number of modular spacings1
Degree of protection (IP)IP20
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 35mm²
Ambient temperature during operating-25 - 55°C
Built-in depth69mm
Rated insulation voltage Ui440V
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated current63A
Concurrently switching neutral conductorNo
Rated voltage230V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271001R0607 | S201M-K63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Release characteristic

K

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

AC/DC

Number of protected poles

1

Current limiting class

3

Additional equipment possible

Over voltage category

3

Number of poles (total)

1

Pollution degree

3

Width in number of modular spacings

1

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Built-in depth

69mm

Rated insulation voltage Ui

440V

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated current

63A

Concurrently switching neutral conductor

Rated voltage

230V

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.