Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category3
Frequency50 - 60Hz
Rated current63A
Power loss5.2W
Built-in depth69mm
Rated insulation voltage Ui440V
Release characteristicZ
Degree of protection (IP)IP20
Explosion-proofNo
Concurrently switching neutral conductorNo
Voltage typeAC/DC
Current limiting class3
Rated voltage230V
Width in number of modular spacings1
Pollution degree3
Number of protected poles1
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0 - 25mm²
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 35mm²
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271001R0608 | S201M-Z63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category

3

Frequency

50 .. 60Hz

Rated current

63A

Power loss

5.2W

Built-in depth

69mm

Rated insulation voltage Ui

440V

Release characteristic

Z

Degree of protection (IP)

IP20

Explosion-proof

Concurrently switching neutral conductor

Voltage type

AC/DC

Current limiting class

3

Rated voltage

230V

Width in number of modular spacings

1

Pollution degree

3

Number of protected poles

1

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 25mm²

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 35mm²

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.