Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current0.5A
Voltage typeAC/DC
Rated voltage230V
Built-in depth69mm
Width in number of modular spacings1
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Release characteristicC
Over voltage category3
Degree of protection (IP)IP20
Current limiting class3
Concurrently switching neutral conductorNo
Pollution degree3
Number of protected poles1
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 25mm²
Number of poles (total)1
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271001R0984 | S201M-C0,5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

0.5A

Voltage type

AC/DC

Rated voltage

230V

Built-in depth

69mm

Width in number of modular spacings

1

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Release characteristic

C

Over voltage category

3

Degree of protection (IP)

IP20

Current limiting class

3

Concurrently switching neutral conductor

Pollution degree

3

Number of protected poles

1

Additional equipment possible

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 25mm²

Number of poles (total)

1

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.