Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Release characteristicC
Rated current10A
Frequency50 - 60Hz
Voltage typeAC/DC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Number of protected poles1
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated insulation voltage Ui440V
Current limiting class3
Over voltage category3
Concurrently switching neutral conductorYes
Number of poles (total)2
Rated voltage230V
Width in number of modular spacings2
Degree of protection (IP)IP20
Additional equipment possibleYes
Built-in depth69mm
Suitable for flush-mounted installationNo
Pollution degree3
Connectable conductor cross section solid-core0 - 35mm²
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271103R0104 | S201M-C10NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Release characteristic

C

Rated current

10A

Frequency

50 .. 60Hz

Voltage type

AC/DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Number of protected poles

1

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated insulation voltage Ui

440V

Current limiting class

3

Over voltage category

3

Concurrently switching neutral conductor

Number of poles (total)

2

Rated voltage

230V

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Additional equipment possible

Built-in depth

69mm

Suitable for flush-mounted installation

Pollution degree

3

Connectable conductor cross section solid-core

0 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.