Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category3
Frequency50 - 60Hz
Degree of protection (IP)IP20
Number of protected poles1
Width in number of modular spacings2
Release characteristicC
Pollution degree3
Current limiting class3
Concurrently switching neutral conductorYes
Rated insulation voltage Ui440V
Suitable for flush-mounted installationNo
Rated voltage230V
Voltage typeAC/DC
Built-in depth69mm
Rated current16A
Connectable conductor cross section solid-core0 - 35mm²
Connectable conductor cross section multi-wired0 - 25mm²
Ambient temperature during operating-25 - 55°C
Additional equipment possibleYes
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271103R0164 | S201M-C16NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category

3

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Number of protected poles

1

Width in number of modular spacings

2

Release characteristic

C

Pollution degree

3

Current limiting class

3

Concurrently switching neutral conductor

Rated insulation voltage Ui

440V

Suitable for flush-mounted installation

Rated voltage

230V

Voltage type

AC/DC

Built-in depth

69mm

Rated current

16A

Connectable conductor cross section solid-core

0 .. 35mm²

Connectable conductor cross section multi-wired

0 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Additional equipment possible

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.