  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Built-in depth69mm
Frequency50 - 60Hz
Release characteristicB
Rated current32A
Degree of protection (IP)IP20
Rated voltage230V
Current limiting class3
Pollution degree3
Rated insulation voltage Ui440V
Width in number of modular spacings2
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Suitable for flush-mounted installationNo
Number of poles (total)2
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Ambient temperature during operating-25 - 55°C
Additional equipment possibleYes
Number of protected poles1
Concurrently switching neutral conductorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271103R0325 | S201M-B32NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Built-in depth

69mm

Frequency

50 .. 60Hz

Release characteristic

B

Rated current

32A

Degree of protection (IP)

IP20

Rated voltage

230V

Current limiting class

3

Pollution degree

3

Rated insulation voltage Ui

440V

Width in number of modular spacings

2

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Suitable for flush-mounted installation

Number of poles (total)

2

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Ambient temperature during operating

-25 .. 55°C

Additional equipment possible

Number of protected poles

1

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.