Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Rated current6A
Built-in depth69mm
Rated voltage230V
Release characteristicK
Frequency50 - 60Hz
Over voltage category3
Rated insulation voltage Ui440V
Current limiting class3
Degree of protection (IP)IP20
Width in number of modular spacings2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Pollution degree3
Number of poles (total)2
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Connectable conductor cross section multi-wired0 - 25mm²
Number of protected poles1
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Concurrently switching neutral conductorYes
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core0 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271103R0377 | S201M-K6NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Rated current

6A

Built-in depth

69mm

Rated voltage

230V

Release characteristic

K

Frequency

50 .. 60Hz

Over voltage category

3

Rated insulation voltage Ui

440V

Current limiting class

3

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Pollution degree

3

Number of poles (total)

2

Additional equipment possible

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Connectable conductor cross section multi-wired

0 .. 25mm²

Number of protected poles

1

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

0 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.