Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Frequency50 - 60Hz
Over voltage category3
Rated insulation voltage Ui440V
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Pollution degree3
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 25mm²
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core0 - 35mm²
Voltage typeAC
Rated current6A
Rated voltage230V
Release characteristicK
Width in number of modular spacings2
Degree of protection (IP)IP20
Number of protected poles1
Concurrently switching neutral conductorYes
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271103R0377 | S201M-K6NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Frequency

50 .. 60Hz

Over voltage category

3

Rated insulation voltage Ui

440V

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Pollution degree

3

Additional equipment possible

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

0 .. 35mm²

Voltage type

AC

Rated current

6A

Rated voltage

230V

Release characteristic

K

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Number of protected poles

1

Concurrently switching neutral conductor

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA