Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Built-in depth69mm
Rated current63A
Rated voltage230V
Release characteristicD
Current limiting class3
Over voltage category3
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of poles (total)2
Frequency50 - 60Hz
Suitable for flush-mounted installationNo
Number of protected poles1
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 25mm²
Width in number of modular spacings2
Pollution degree3
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 55°C
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271103R0631 | S201M-D63NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Built-in depth

69mm

Rated current

63A

Rated voltage

230V

Release characteristic

D

Current limiting class

3

Over voltage category

3

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of poles (total)

2

Frequency

50 .. 60Hz

Suitable for flush-mounted installation

Number of protected poles

1

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Width in number of modular spacings

2

Pollution degree

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.