Technical specifications

Frequency50 - 60Hz
Built-in depth69mm
Voltage typeAC/DC
Rated voltage230V
Release characteristicC
Rated current1.6A
Rated insulation voltage Ui440V
Current limiting class3
Number of protected poles1
Width in number of modular spacings2
Over voltage category3
Connectable conductor cross section multi-wired0 - 25mm²
Suitable for flush-mounted installationNo
Pollution degree3
Concurrently switching neutral conductorYes
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Ambient temperature during operating-25 - 55°C
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)2
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271103R0974 | S201M-C1,6NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Built-in depth

69mm

Voltage type

AC/DC

Rated voltage

230V

Release characteristic

C

Rated current

1.6A

Rated insulation voltage Ui

440V

Current limiting class

3

Number of protected poles

1

Width in number of modular spacings

2

Over voltage category

3

Connectable conductor cross section multi-wired

0 .. 25mm²

Suitable for flush-mounted installation

Pollution degree

3

Concurrently switching neutral conductor

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Ambient temperature during operating

-25 .. 55°C

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

2

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.