Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Connectable conductor cross section multi-wired0 - 25mm²
Over voltage category3
Pollution degree3
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Width in number of modular spacings2
Additional equipment possibleYes
Current limiting class3
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Number of protected poles1
Release characteristicC
Rated voltage230V
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated current0.5A
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271103R0984 | S201M-C0,5NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Connectable conductor cross section multi-wired

0 .. 25mm²

Over voltage category

3

Pollution degree

3

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Width in number of modular spacings

2

Additional equipment possible

Current limiting class

3

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

1

Release characteristic

C

Rated voltage

230V

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated current

0.5A

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.