  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Voltage typeAC/DC
Rated current25A
Current limiting class3
Rated voltage400V
Release characteristicD
Built-in depth71mm
Rated insulation voltage Ui440V
Over voltage category3
Pollution degree3
Width in number of modular spacings2
Number of protected poles2
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 55°C
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Connectable conductor cross section solid-core0 - 35mm²
Additional equipment possibleYes
Number of poles (total)2
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272001R0251 | S202M-D25

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Voltage type

AC/DC

Rated current

25A

Current limiting class

3

Rated voltage

400V

Release characteristic

D

Built-in depth

71mm

Rated insulation voltage Ui

440V

Over voltage category

3

Pollution degree

3

Width in number of modular spacings

2

Number of protected poles

2

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 55°C

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Connectable conductor cross section solid-core

0 .. 35mm²

Additional equipment possible

Number of poles (total)

2

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA