Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Built-in depth71mm
Rated current3A
Rated voltage400V
Degree of protection (IP)IP20
Width in number of modular spacings2
Pollution degree3
Release characteristicK
Over voltage category3
Rated insulation voltage Ui440V
Current limiting class3
Number of protected poles2
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Number of poles (total)2
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 55°C

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272001R0317 | S202M-K3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Built-in depth

71mm

Rated current

3A

Rated voltage

400V

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Pollution degree

3

Release characteristic

K

Over voltage category

3

Rated insulation voltage Ui

440V

Current limiting class

3

Number of protected poles

2

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Number of poles (total)

2

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 55°C

From same serie