Aleta.hr
Main Product Image

2CDS272001R0577 | S202M-K50

Code: 1549916

ManufacturerABB
Catalog number2CDS272001R0577
EAN code4016779600828

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles2
Number of poles (total)2
Rated voltage400V
Rated current50A
Release characteristicK
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Voltage typeAC/DC
Current limiting class3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Pollution degree3
Additional equipment possibleYes
Width in number of modular spacings2
Concurrently switching neutral conductorNo
Over voltage category3
Built-in depth71mm
Connectable conductor cross section multi-wired0 - 25mm²
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 35mm²
Degree of protection (IP)IP20
Suitable for flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272001R0577 | S202M-K50

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

2

Number of poles (total)

2

Rated voltage

400V

Rated current

50A

Release characteristic

K

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Voltage type

AC/DC

Current limiting class

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Pollution degree

3

Additional equipment possible

Width in number of modular spacings

2

Concurrently switching neutral conductor

Over voltage category

3

Built-in depth

71mm

Connectable conductor cross section multi-wired

0 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 35mm²

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.