Technical specifications

Number of poles (total)3
Release characteristicD
Rated current1A
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Additional equipment possibleYes
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Pollution degree3
Width in number of modular spacings3
Rated voltage400V
Current limiting class3
Connectable conductor cross section solid-core0 - 35mm²
Connectable conductor cross section multi-wired0 - 25mm²
Voltage typeAC/DC
Ambient temperature during operating-25 - 55°C
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Frequency50 - 60Hz
Suitable for flush-mounted installationNo
Number of protected poles3
Over voltage category3
Built-in depth69mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273001R0011 | S203M-D1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

3

Release characteristic

D

Rated current

1A

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Additional equipment possible

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Pollution degree

3

Width in number of modular spacings

3

Rated voltage

400V

Current limiting class

3

Connectable conductor cross section solid-core

0 .. 35mm²

Connectable conductor cross section multi-wired

0 .. 25mm²

Voltage type

AC/DC

Ambient temperature during operating

-25 .. 55°C

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Frequency

50 .. 60Hz

Suitable for flush-mounted installation

Number of protected poles

3

Over voltage category

3

Built-in depth

69mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.